DGH DIN-150 Modbus Voltage Input Module

Product Features

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.05% of full scale maximum
  • 10µV (mV spans), 0.02% of the full scale on V span
  • Common mode rejection: 100dB at 50/60Hz
  • Digital filtering
  • Temperature range of -25°C to +70°C
  • Non-compliant

The DIN-150 MODBUS bridge input modules are part of the DGH’s DIN-100 data acquisition module family. This input module converts analog input signal from the choice of two different bridge ranges (±30mV or ±60mV) with option of two different excitations (5V or 10V), using the MODBUS RTU protocol to digital data at the rate of 8 conversions per second, storing the latest result in the buffer. The signal is transmitted to the computer or other processor-based controlling equipment using RS-485 port; if this is not available a DIN-191 converter to RS-232 can be used. The DIN-150 modules can be directly connected to a sensor and perform signal conditioning, linearisation, scaling and conversion to both ASCII and MODBUS values. For extra security, it utilises a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The DIN-150 comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be easily changed by the user. The modules require no special software and can be connected and started up quickly and easily, however a utility software is available at no extra charge if required. The DIN-150 can be mounted on a DIN-rail directly, without need for a mounting kit.

  • Single channel analog-to-digital bridge input module
  • RS-485 output
  • Choice of 2 different bridge ranges: 30mV or 60mV
  • Choice of excitation voltage: 5V or 10V DC @ 60mA maximum
  • Communicates using MODBUS RTU protocol
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.05% of the full scale
  • Resolution: 10µV (mV spans), 0.02% of the full scale on V span
  • Offset Control: Full input range
  • Input protection to 30 Vdc
  • 2 programmable single-pole digital filters for smoothing analog data
  • Power requirements: Serial = 0.75W
  • Temperature range -25°C to +70°C

 

The applications for the DIN-150 data acquisition modules include:

  • Process monitoring and control
  • Remote data logging to any host computer
  • Product testing
  • Interface to PLC

 

Specifications

Weight 0.00000 kg
Dimensions 25.40 x 83.80 x 86.40mm
Excitation

5V, 10V

Input

±30mV, ±60mV

Input/Output

1 Analog Input, 1 Digital Output

Number of Channels

1 Channel

Power Requirements

Unregulated +10V to +30Vdc Serial 0.75W maximum

Series / Model

Product Variations

SKUExcitationInput 
DGH DIN-150 Modbus Voltage Input Module10V±30mV

Request Quote

DGH DIN-150 Modbus Voltage Input Module5V±30mV

Request Quote

DGH DIN-150 Modbus Voltage Input Module10V±60mV

Request Quote

DGH DIN-150 Modbus Voltage Input Module5V±60mV

Request Quote

  • DGH

DGH DIN-150 Modbus Voltage Input Module