DGH DIN-140 Modbus Voltage Input Module

  • DGH

Product Features

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.01% of reading ±10µs
  • Resolution: 0.005% of reading +0.01Hz
  • Temperature coefficient: ±20ppm/°C
  • Input impedance: 1MΩ minimum
  • Digital filtering
  • Hysteresis: adjustable 10mV to 1V
  • Temperature range of -25°C to +70°C

Applications

  • Non-compliant

The DIN-160 MODBUS Frequency input modules are part of the DGH’s DIN-100 data acquisition module family. This input module converts analog frequency input signal (1Hz-20kHz) using the MODBUS RTU protocol to digital data at the rate of 8 conversions per second, storing the latest result in the buffer. The signal is transmitted to the computer or other processor-based controlling equipment using RS-485 port; if this is not available a DIN-191 converter to RS-232 can be used. The DIN-160 module can be directly connected to a sensor and perform signal conditioning, linearisation, scaling and conversion to both ASCII and MODBUS values. For extra security, it utilises a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The DIN-160 comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be easily changed by the user. The modules require no special software and can be connected and started up quickly and easily, however a utility software is available at no extra charge if required. The DIN-160 can be mounted on a DIN-rail directly, without need for a mounting kit.

  • Single channel analog-to-digital frequency input module
  • RS-485 output
  • Frequency input: 1Hz to 20kHz
  • Communicates using MODBUS RTU protocol
  • User-selectable features include analog input range, baud rate, parity type, switching level (0V or 2.5V) and others
  • Accuracy: ±0.01% of reading ±10µs
  • Resolution: 0.005% of reading +0.01Hz
  • Hysteresis: Adjustable 10mV to 1V
  • Input burnout protection to 250 Vac
  • 2 programmable single-pole digital filters for smoothing analog data
  • Power requirements: Serial = 0.75W
  • Temperature range -25°C to +70°C

 

The applications for the DIN-160 data acquisition modules include:

  • Process monitoring and control
  • Remote data logging to any host computer
  • Product testing
  • Interface to PLC

 

Specifications

Weight 0.00000 kg
Dimensions 25.40 x 83.80 x 86.40mm
Alpha Value

0.00385 (-200°C to +850°C), 0.00388 (-100°C to +125°C), 0.00392 (-200°C to +600°C)

Input/Output

1 Analog Input, 1 Digital Output

Number of Channels

1 Channel

Power Requirements

Unregulated +10V to +30Vdc Serial 0.75W maximum

Series / Model

DGH DIN-100 Technical Library

We are pleased to provide you with a range of additional content including videos, product datasheets, case studies, white papers and application notes for your reference. Please see below for the latest content available:

 

 

DOCUMENTATION
DGH DIN-100 Series Datasheet
DGH DIN-100 Series User Manual
Command set for DIN-100 Series
MODBUS RTU Function List
MODBUS RTU Protocol Overview

Related Products

  • DGH

DGH DIN-140 Modbus Voltage Input Module