Analog Input / Output

  • DGH
  • Intelligent features not found in the D1000 series: built-in commands to create custom nonlinear input-to-output transfer functions
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Resolution: 10ฮผV (mV spans) and 0.02% of FS (V spans)
  • Common mode rejection: 100dB at 50/60Hz
  • Excitation voltage: 5V, 8V or 10V dc @ 60mA maximum
  • Offset Control: Full input range
  • Input burnout protection to 30Vdc
  • Zero drift: +/-1ฮผV/deg C maximum
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • Intelligent features not found in the D1000 series: built-in commands to create custom nonlinear input-to-output transfer functions
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.01% of reading, ยฑ10ฮผs for timer models or ยฑ0.01Hz for frequency models
  • Resolution: ยฑ0.005% of reading, ยฑ0.01ฮผs for timer models or ยฑ0.01Hz for frequency models
  • Input Impedance: 1Mฮฉ minimum
  • Span temperature coefficient: ยฑ20ppm/ยฐC for frequency and timer models
  • Adjustable hysteresis (1mV to 1V)
  • Input protection to 250Vac
  • User-selectable switching level (0V or +2.5V)
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 12-bit DAC, 1000 conversions per second
  • Accuracy: ยฑ0.1% of FS maximum
  • Zero drift ยฑ30ยตV/ยฐC
  • Output Isolation of 500V rms
  • Settling time to 0.1% of FS: 300ยตs typical, 1ms maximum
  • Voltage levels of ยฑ30V without damage
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • Programmable output slopes and watchdog timer
  • 12-bit DAC, 1000 conversions per second
  • Accuracy: ยฑ0.1% of FS maximum
  • Zero drift ยฑ30ยตV/ยฐC
  • Output Isolation of 500V rms
  • Settling time to 0.1% of FS: 300ยตs typical, 1ms maximum
  • Voltage levels of ยฑ30V without damage
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 12-bit DAC, 1000 conversions per second
  • Accuracy: ยฑ0.1% of FS maximum
  • Output Isolation of 500V rms
  • Settling time to 0.1% of FS: 300ยตs typical, 1ms maximum
  • Voltage levels of ยฑ30V without damage
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • Programmable output slopes and watchdog timer
  • 12-bit DAC, 1000 conversions per second
  • Accuracy: ยฑ0.1% of FS maximum
  • Output Isolation of 500V rms
  • Settling time to 0.1% of FS: 300ยตs typical, 1ms maximum
  • Voltage levels of ยฑ30V without damage
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • Programmable features: output slopes, data scaling, starting value and watchdog timer
  • 12-bit DAC, 1000 conversions per second
  • Accuracy: ยฑ0.1% of FS maximum
  • Zero drift ยฑ30ยตV/ยฐC
  • Output Isolation of 500V rms
  • Settling time to 0.1% of FS: 300ยตs typical, 1ms maximum
  • Voltage levels of ยฑ30V without damage
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • Programmable features: output slopes, data scaling, starting value and watchdog timer
  • 12-bit DAC, 1000 conversions per second
  • Accuracy: ยฑ0.1% of FS maximum
  • Zero drift ยฑ1.0ยตA/ยฐC
  • Output Isolation of 500V rms
  • Settling time to 0.1% of FS: 300ยตs typical, 1ms maximum
  • Current output compliance voltage of ยฑ12V
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Input impedance of โ‰คยฑ1V input =100Mโ„ฆ minimum and โ‰ฅยฑ5V input =1Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Input impedance of โ‰คยฑ1V input =100Mโ„ฆ minimum and โ‰ฅยฑ5V input =1Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ0.04% of FS maximum
  • Resolution: 0.04% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Voltage drop: ยฑ1V maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ0.04% of FS maximum
  • Resolution: 0.04% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Voltage drop: ยฑ1V maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ1ยฐC
  • Resolution: 1ยฐC
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Input burnout protection to 250Vac
  • Input impedance 100Mฮฉ minimum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ1ยฐC
  • Resolution: 1ยฐC
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Input burnout protection to 250Vac
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ0.1ยฐC
  • Resolution: 0.01ยฐC
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Input burnout protection to 30Vdc
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH
  • 8 conversions per second
  • Accuracy: ยฑ0.1ยฐC
  • Resolution: 0.01ยฐC
  • Common mode rejection: 100dB at 50/60Hz
  • Autozero and Autocalibration
  • Input burnout protection to 30Vdc
  • Temperature range of -25ยฐC to +70ยฐC

Manufacturers

Looking for Analog Input / Output?

Looking for Analog Input / Output?

The below manufacturers are all of our authorised partners that produce Analog Input / Output or related products.

Analog Input / Output

The DGH analog input/output modules are complete data acquisition systems designed for use with PLCโ€™s, PCs and other processor-based equipment. These modules provide a direct connection to a vast array of industrial sensors including DC voltages, 4-20mA current loops, thermocouples, RTD probes, thermistors, load cells, frequency sources and more.

The modules contain an isolated analog input, perform all signal conditioning, high resolution A/D conversion, linearisation, and scale the digital data values into engineering units. Data values are communicated to a host computer using either the DGH ASCII serial protocol, the Modbus RTU serial protocol or the Modbus TCP Ethernet protocol. Each module is available with a serial, USB or Ethernet interface.