• DGH

DGH D1100 Sensor to Computer Interface Voltage Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Input impedance of โ‰คยฑ1V input =100Mโ„ฆ minimum and โ‰ฅยฑ5V input =1Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1100M Modbus with Voltage Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Input impedance of โ‰คยฑ1V input =100Mโ„ฆ minimum and โ‰ฅยฑ5V input =1Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1200 Sensor to Computer Interface Current Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum (0.04% of FS for 4-20mA option)
  • Resolution: 0.01% of FS (4 digits) (0.04% of FS for 4-20mA option)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1200M Modbus with Current Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum (0.04% of FS for 4-20mA option)
  • Resolution: 0.01% of FS (4 digits) (0.04% of FS for 4-20mA option)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1300 Sensor to Computer Thermocouple Input Module

  • 8-bit ADC, 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy (overall, error from all sources, between 0-40ยฐC ambient): ยฑ1.0ยฐC maximum (J, K, T, E) and ยฑ2.5 ยฐC maximum (R, S, B, C)(300ยฐC TO FS)
  • Resolution: ยฑ1ยฐ
  • Common mode rejection: 100dB at 50/60Hz
  • Input impedance: 100Mโ„ฆ minimum
  • Lead resistance effect: <20ฮผV per 350โ„ฆ
  • Open thermocouple and overrange indication
  • Automatic cold junction compensation and linearization
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1300M Modbus with Thermocouple Input Module Series

  • 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy (overall, error from all sources, between 0-40ยฐC ambient): ยฑ1.0ยฐC maximum (J, K, T, E) and ยฑ2.5 ยฐC maximum (R, S, B, C)(300ยฐC TO FS)
  • Resolution: ยฑ1ยฐ
  • Common mode rejection: 100dB at 50/60Hz
  • Input impedance: 100Mโ„ฆ minimum
  • Lead resistance effect: <20ฮผV per 350โ„ฆ
  • Open thermocouple and overrange indication
  • Automatic cold junction compensation and linearization
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1400 Sensor to Computer Interface RTD Input Module Series

  • 8-bit ADC, 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.3ยฐC maximum
  • Resolution: ยฑ0.1ยฐ (C or F)
  • Common mode rejection: 100dB at 50/60Hz
  • Input connections: 2-, 3- or 4-wire
  • Lead resistance effect: 3-wire – 2.5ยฐC per โ„ฆ of imbalance, 4-wire – negligible
  • Max lead resistance: 50โ„ฆ
  • Automatic linearisation and lead compensation
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1400M Modbus with RTD Input Module Series

  • 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.3ยฐC maximum
  • Resolution: ยฑ0.1ยฐ (C or F)
  • Common mode rejection: 100dB at 50/60Hz
  • Input connections: 2-, 3- or 4-wire
  • Lead resistance effect: 3-wire – 2.5ยฐC per โ„ฆ of imbalance, 4-wire – negligible
  • Max lead resistance: 50โ„ฆ
  • Automatic linearisation and lead compensation
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1450 Sensor to Computer Interface Thermistor Input Module

  • 8-bit ADC, 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.1ยฐC for 2252โ„ฆ and ยฑ0.2ยฐC for TD series
  • Resolution: 0.01ยฐ (C or F) for 2252โ„ฆ and 0.1ยฐ(C or F) for TD series
  • Common mode rejection: 100dB at 50/60Hz
  • Input protection to 30Vdc
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1450M Modbus Thermistor Input Module Series

  • 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.1ยฐC for 2252โ„ฆ and ยฑ0.2ยฐC for TD series
  • Resolution: 0.01ยฐ (C or F) for 2252โ„ฆ and 0.1ยฐ(C or F) for TD series
  • Common mode rejection: 100dB at 50/60Hz
  • Input protection to 30Vdc
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1500 Sensor to Computer Interface Bridge Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Resolution: 10ฮผV (mV spans) and 0.02% of FS (V spans)
  • Common mode rejection: 100dB at 50/60Hz
  • Excitation voltage: 5V, 8V or 10V dc @ 60mA maximum
  • Offset Control: Full input range
  • Input burnout protection to 30Vdc
  • Zero drift: +/-1ฮผV/deg C maximum
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1500M Modbus Bridge Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Resolution: 10ฮผV (mV spans) and 0.02% of FS (V spans)
  • Common mode rejection: 100dB at 50/60Hz
  • Excitation voltage: 5V, 8V or 10V dc @ 60mA maximum
  • Offset Control: Full input range
  • Input burnout protection to 30Vdc
  • Zero drift: +/-1ฮผV/deg C maximum
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1600 Sensor to Computer Interface Frequency Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.01% of reading, ยฑ10ฮผs for timer models or ยฑ0.01Hz for frequency models
  • Resolution: ยฑ0.005% of reading, ยฑ0.01ฮผs for timer models or ยฑ0.01Hz for frequency models
  • Input Impedance: 1Mฮฉ minimum
  • Span temperature coefficient: ยฑ20ppm/ยฐC for frequency and timer models
  • Adjustable hysteresis (1mV to 1V)
  • Input protection to 250Vac
  • User-selectable switching level (0V or +2.5V)
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1600M Modbus Frequency Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.01% of reading,plus ยฑ0.01Hz
  • Resolution: ยฑ0.005% of reading, plus ยฑ0.01Hz
  • Input Impedance: 1Mฮฉ minimum
  • Span temperature coefficient: ยฑ20ppm/ยฐC
  • Adjustable hysteresis (1mV to 1V)
  • Input protection to 250Vac
  • User-selectable switching level (0V or +2.5V)
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1700 Digital Input/Output Module

  • 16-bit ADC, 25/20 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Voltage drop: 2.0V maximum
  • Input impedance 20Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC
  • DGH

DGH D1700M Digital Input/Output Module

  • 16-bit ADC, 25/20 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Voltage drop: 2.0V maximum
  • Input impedance 20Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1100 Sensor to Computer Interface Voltage Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Input impedance of โ‰คยฑ1V input =100Mโ„ฆ minimum and โ‰ฅยฑ5V input =1Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1100M Modbus with Voltage Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Input impedance of โ‰คยฑ1V input =100Mโ„ฆ minimum and โ‰ฅยฑ5V input =1Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1200 Sensor to Computer Interface Current Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum (0.04% of FS for 4-20mA option)
  • Resolution: 0.01% of FS (4 digits) (0.04% of FS for 4-20mA option)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1200M Modbus with Current Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.02% of FS maximum (0.04% of FS for 4-20mA option)
  • Resolution: 0.01% of FS (4 digits) (0.04% of FS for 4-20mA option)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ยฑ1 count maximum (autozero)
  • Voltage drop: ยฑ0.1V maximum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1300 Sensor to Computer Thermocouple Input Module

  • 8-bit ADC, 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy (overall, error from all sources, between 0-40ยฐC ambient): ยฑ1.0ยฐC maximum (J, K, T, E) and ยฑ2.5 ยฐC maximum (R, S, B, C)(300ยฐC TO FS)
  • Resolution: ยฑ1ยฐ
  • Common mode rejection: 100dB at 50/60Hz
  • Input impedance: 100Mโ„ฆ minimum
  • Lead resistance effect: <20ฮผV per 350โ„ฆ
  • Open thermocouple and overrange indication
  • Automatic cold junction compensation and linearization
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1300M Modbus with Thermocouple Input Module Series

  • 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy (overall, error from all sources, between 0-40ยฐC ambient): ยฑ1.0ยฐC maximum (J, K, T, E) and ยฑ2.5 ยฐC maximum (R, S, B, C)(300ยฐC TO FS)
  • Resolution: ยฑ1ยฐ
  • Common mode rejection: 100dB at 50/60Hz
  • Input impedance: 100Mโ„ฆ minimum
  • Lead resistance effect: <20ฮผV per 350โ„ฆ
  • Open thermocouple and overrange indication
  • Automatic cold junction compensation and linearization
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1400 Sensor to Computer Interface RTD Input Module Series

  • 8-bit ADC, 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.3ยฐC maximum
  • Resolution: ยฑ0.1ยฐ (C or F)
  • Common mode rejection: 100dB at 50/60Hz
  • Input connections: 2-, 3- or 4-wire
  • Lead resistance effect: 3-wire – 2.5ยฐC per โ„ฆ of imbalance, 4-wire – negligible
  • Max lead resistance: 50โ„ฆ
  • Automatic linearisation and lead compensation
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1400M Modbus with RTD Input Module Series

  • 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.3ยฐC maximum
  • Resolution: ยฑ0.1ยฐ (C or F)
  • Common mode rejection: 100dB at 50/60Hz
  • Input connections: 2-, 3- or 4-wire
  • Lead resistance effect: 3-wire – 2.5ยฐC per โ„ฆ of imbalance, 4-wire – negligible
  • Max lead resistance: 50โ„ฆ
  • Automatic linearisation and lead compensation
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1450 Sensor to Computer Interface Thermistor Input Module

  • 8-bit ADC, 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.1ยฐC for 2252โ„ฆ and ยฑ0.2ยฐC for TD series
  • Resolution: 0.01ยฐ (C or F) for 2252โ„ฆ and 0.1ยฐ(C or F) for TD series
  • Common mode rejection: 100dB at 50/60Hz
  • Input protection to 30Vdc
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1450M Modbus Thermistor Input Module Series

  • 8 conversions per second
  • User selectable ยฐC or ยฐF
  • Accuracy: ยฑ0.1ยฐC for 2252โ„ฆ and ยฑ0.2ยฐC for TD series
  • Resolution: 0.01ยฐ (C or F) for 2252โ„ฆ and 0.1ยฐ(C or F) for TD series
  • Common mode rejection: 100dB at 50/60Hz
  • Input protection to 30Vdc
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1500 Sensor to Computer Interface Bridge Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Resolution: 10ฮผV (mV spans) and 0.02% of FS (V spans)
  • Common mode rejection: 100dB at 50/60Hz
  • Excitation voltage: 5V, 8V or 10V dc @ 60mA maximum
  • Offset Control: Full input range
  • Input burnout protection to 30Vdc
  • Zero drift: +/-1ฮผV/deg C maximum
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1500M Modbus Bridge Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Resolution: 10ฮผV (mV spans) and 0.02% of FS (V spans)
  • Common mode rejection: 100dB at 50/60Hz
  • Excitation voltage: 5V, 8V or 10V dc @ 60mA maximum
  • Offset Control: Full input range
  • Input burnout protection to 30Vdc
  • Zero drift: +/-1ฮผV/deg C maximum
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1600 Sensor to Computer Interface Frequency Input Module

  • 8-bit ADC, 8 conversions per second
  • Accuracy: ยฑ0.01% of reading, ยฑ10ฮผs for timer models or ยฑ0.01Hz for frequency models
  • Resolution: ยฑ0.005% of reading, ยฑ0.01ฮผs for timer models or ยฑ0.01Hz for frequency models
  • Input Impedance: 1Mฮฉ minimum
  • Span temperature coefficient: ยฑ20ppm/ยฐC for frequency and timer models
  • Adjustable hysteresis (1mV to 1V)
  • Input protection to 250Vac
  • User-selectable switching level (0V or +2.5V)
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1600M Modbus Frequency Input Module Series

  • 8 conversions per second
  • Accuracy: ยฑ0.01% of reading,plus ยฑ0.01Hz
  • Resolution: ยฑ0.005% of reading, plus ยฑ0.01Hz
  • Input Impedance: 1Mฮฉ minimum
  • Span temperature coefficient: ยฑ20ppm/ยฐC
  • Adjustable hysteresis (1mV to 1V)
  • Input protection to 250Vac
  • User-selectable switching level (0V or +2.5V)
  • Span temperature coefficient: ยฑ50ppm/ยฐC maximum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1700 Digital Input/Output Module

  • 16-bit ADC, 25/20 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Voltage drop: 2.0V maximum
  • Input impedance 20Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC

DGH D1700M Digital Input/Output Module

  • 16-bit ADC, 25/20 conversions per second
  • Accuracy: ยฑ0.05% of FS maximum
  • Voltage drop: 2.0V maximum
  • Input impedance 20Mโ„ฆ minimum
  • Temperature range of -25ยฐC to +70ยฐC

Manufacturers

Looking for Data Acquisition Modules?

The below manufacturers are all of our authorised partners that produce Data Acquisition Modules or related products.

Data Acquisition Modules

We offer a full range of modular data acquisition modules brought to us by DGH. These include:

  • Analog Input
  • Analog Output
  • Digital Input/Output
  • Accessories

These products offer a versatile solution extremely popular for process monitoring, water & wastewater management, pharmaceutical, scientific laboratories, military and power utilities.

Need more information? Speak to our technical sales team who can discuss your project or product and provide technical advice. Speak to us now!