Custom Product series
- Steel mill pressure transducer
- Pressures up to 350 Bar
- Accuracy down to โคยฑ0.25% BFSL
- Pressure cycles of >100 million
- Burst pressure of 10X or 20,000 PSI (whichever is less)
- IP69 protection against high pressure washdown
- Integral snubber protects against pressure transients
- Industrial pressure transducer
- Pressure ranges from vacuum up to 45,000 PSI
- Accuracy down to โค ยฑ0.25% BFSL
- Stability (1 year) of โค ยฑ0.25% of FS
- Overpressure of 2x minimum
- Temperature range from -40ยฐC to +85ยฐC
- Media Temperature from -40ยฐC to +120ยฐC
- Compact media isolated pressure sensor
- Pressure ranges from 0-2 up to 2,000 PSI
- Accuracy as low as โค ยฑ0.25% BFSL
- Stability of โค ยฑ0.2% of FS (1 year)
- Pressure cycles of 10 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 4,000 PSI
- Submersible pressure transducer
- Pressure ranges from 1 to 100 PSI
- Accuracy down to โคยฑ0.25% BFSL
- Stability (1 year) of โคยฑ0.25% of FS
- Pressure cycles of 50 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 500 PSI
- Wet/wet differential pressure transducer
- Differential pressure ranges up to 300 PSI
- Line pressure up to 500 PSI
- Accuracy of โคยฑ0.25% BFSL at 25ยฐC
- Stability of โคยฑ0.25% of FS
- Pressure cycles of 4 million
- Overpressure of 2x or 500 PSI
- Non-Clogging submersible pressure transducer
- Pressure ranges from 2 PSI to 50 PSI
- Flush diaphragm prevents clogging
- Hastelloy C276 diaphragm material
- IP68 rated
- Operating temperature of -40 to +85ยฐC
- Compensated temperatures from 0 to +55ยฐC
- Non-incendive pressure transducer
- Pressure ranges from 50 PSI to 30,000 PSI
- Accuracy of โคยฑ0.25% BFSL at 25ยฐC
- Stability of โคยฑ0.25% of FS
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 60,000 PSI
- Non-incendive low pressure transducer
- Pressure ranges from 1 PSI up to 49 PSI
- Temperature range from โ20ยฐC up to +80ยฐC *
- Accuracy of โคยฑ0.25% BFSL at 25ยฐC **
- Stability of โคยฑ0.25% of FS (1 year)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Non-Incendive Differential Pressure Transducer
- Differential pressure up to 50 PSI
- Line pressure up to 500 PSI
- Accuracy of โคยฑ0.25% BFSL / โคยฑ0.5% BFSL (2 PSI & below)
- Overpressure of 2X or 500 PSI (whichever is less)
- Temperature range โ40ยฐC to +80ยฐC
- Media temperature of -40 to +125ยฐC
- Explosion-Proof Pressure Transducer
- Pressure ranges from 50 PSI to 30,000 PSI
- One piece diaphragm design – No internal O-rings or welds
- Factory sealed stainless steel case – Withstands harsh environments
- Accuracy of โคยฑ0.25% BFSL at 25ยฐC (<10,000 PSI)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Intrinsically safe pressure transducer
- Pressure ranges available from 50 PSI up to 30,000 PSI
- Temperature range โ40ยฐC to +85ยฐC
- Accuracy of โค ยฑ0.25% BFSL
- Burst pressure of 5x or 60,000 PSI whichever is less
- Stability (1 year) of โค ยฑ0.25% of FS
- Pressure cycles of 100 million
- Intrinsically safe low pressure transducer
- Pressure ranges from 1 PSI to 49 PSI
- Accuracy of โคยฑ0.25% BFSL
- Stability of โคยฑ0.25% of FS (1 year)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 245 PSI
- Intrinsically safe submersible pressure transducer
- Pressure ranges from 1 PSI up to 50 PSI
- Accuracy of โคยฑ0.25% BFSL
- Stability of โคยฑ0.25% of FS (1 year)
- Pressure cycles of 50 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 250 PSI
- Intrinsically safe differential pressure transducer
- Differential pressure up to 50 PSI
- Maximum line pressure of 500 PSI
- Bi-directional pressure ranges
- Accuracy of โคยฑ0.25% BFSL
- Stability of โคยฑ0.25% of FS
- Pressure cycles of 4 million
- Differential pressure transducer
- Very low thermal sensitivity shift of ยฑ0.01% of F.S. perยฐC
- Small, lightweight manifold style mounting for easy installation
- Temperature compensated design provides highly accurate pressure measurements
- Shock and vibration resistant design offers highly accurate and reliable pressure monitoring in many operating conditions
- Durable solution withstands harsh environments for long-lasting performance
- Custom electrical connection and pressure port adaptors are available on request
- Differential pressure transducer
- Thermal sensitivity shift of ยฑ0.01% of F.S. per ยฐC
- Small, lightweight manifold style mounting for easy installation
- Shock and vibration resistant design offers highly accurate and reliable pressure monitoring in many operating conditions
- Compact design for an easy-to-use differential measurement solution
- Durable solution withstands harsh environments for long-lasting performance
- Custom electrical connection and pressure port adaptors are available on request