Renewables

We have designed various sensors and components for some of the largest renewable energy companies around as well as also helped with small startup companies investigating Wind, Wave and Tidal renewable projects. Whether you need a sensor to monitor hydraulic spikes or a braking resistor to help with turbine dumped energy, we are here to help.

  • RARA
  • Metal clad thick film resistor
  • Resistance range from 1kฮฉ to 2Mฮฉ
  • Max power rating of 25W
  • Cement moulding within aluminium housing
  • Short time overload of 2 x power rating is 5 seconds
  • High stability at conventional power ratings
  • Temperature range of -55ยฐC up to +250ยฐC
[Download not found]
  • Compliant
  • RARA
  • Metal clad wire wound economy resistor
  • Inductive resistance between 0.1ฮฉ and 270ฮฉ
  • Non-inductive resistance between 0.1ฮฉ and 56ฮฉ
  • Power rating of 60W
  • Insulation resistance of 20Mฮฉ minimum
  • Short time overload of 5 x power rating is 5 seconds
  • RARA
  • Metal clad wire wound economy resistor
  • Inductive resistance between 0.1ฮฉ and 910ฮฉ
  • Non-inductive resistance between 0.1ฮฉ and 110ฮฉ
  • Power rating of 80W
  • Insulation resistance of 20Mฮฉ minimum
  • Short time overload of 10 x power rating is 5 seconds
  • RARA
  • Metal clad wire wound economy resistor
  • Inductive resistance between 0.1ฮฉ and 1.3kฮฉ
  • Non-inductive resistance between 0.1ฮฉ and 300ฮฉ
  • Power rating of 120W
  • Insulation resistance of 20Mฮฉ minimum
  • Short time overload of 10 x power rating is 5 seconds
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 1.1kฮฉ
  • Power rating of 100W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 1.75kฮฉ
  • Power rating of 150W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 2.2kฮฉ
  • Power rating of 200W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 2.79kฮฉ
  • Power rating of 250W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 3.5kฮฉ
  • Power rating of 300W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 4.45kฮฉ
  • Power rating of 400W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Flat type metal clad wire wound resistor
  • Resistance options from 1ฮฉ up to 5.78kฮฉ
  • Power rating of 500W (on a heat sink)
  • Tolerance options between ยฑ0.5% and ยฑ10.0%
  • TCR of +260 ppm/ยฐC maximum
  • For UL Approval see the ULF Series
  • RARA
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20Mฮฉ minimum
  • Temperature range of -55ยฐC up to +200ยฐC
  • Extruded aluminium horizontal housing
  • Short time overload of 5 x power rating is 5 seconds
  • RARA
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20Mฮฉ minimum
  • Temperature range of -55ยฐC up to +200ยฐC
  • Extruded aluminium horizontal housing
  • Short time overload of 10 x power rating is 5 seconds
  • RARA
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20Mฮฉ minimum
  • Temperature range of -55ยฐC up to +200ยฐC
  • Extruded aluminium horizontal housing
  • Short time overload of 10 x power rating is 5 seconds
  • RARA
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20Mฮฉ minimum
  • Temperature range of -55ยฐC up to +200ยฐC
  • Extruded aluminium horizontal housing
  • Short time overload of 10 x power rating is 5 seconds
  • RARA
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20Mฮฉ minimum
  • Temperature range of -55ยฐC up to +200ยฐC
  • Extruded aluminium horizontal housing
  • Short time overload of 10 x power rating is 5 seconds